Also, following advantages;
1. no frequency mis-match problem and hence helps in Grid synchronization of two different Reason.
2. Better control over power flow by controlling the Load angle.
3. Easy transmission for long distance lines, as there is no Capacitive voltage increment ( due to Ferranti effect ).
Disadvantages:
More complicated and initial cost of the plant is many times higher than that for the terminal equipments of AC stations of same capacity.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment
In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.
what are the specifications we must look at to select a relay for any capacity motor?
Can any one know what are the symbols at the down (below) the analog ammeter??? there are 4 symbols which are they ?????
When can we take Neutral as common neutral link?
we need a ntpc previous papers
what is static frequency converter?what is the function...of sfc...?
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?
What is the function of RCBO? What are the different sensitivity ratings & each application?
which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?
what is meant by skew width in machines?
Pleae send me last 5 years of Question book about RRB chennai.
300m long and 30kw inductive loade 3phase supply how many size cable required
1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.