Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

could i arrange a faulty and healthey battery bank togather
in parallel , if your ans is not then why?

Answer Posted / abhishek goyal

No because faulty battery bank both rod or plates are melt
we also called it might be short. so if we connect the
faulty battery bank into parallel connection with healthy
battery it will be discharge through the faulty battery.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1726


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

781


What is the role of Dedicated earthing in UPS System?

3078


In HVDC LINE RECTIFIER CONTROL ON CONSTANT CURRENT AND INVERTER CONTROL CONSTANT EXITATION ANGLE CONTROL BUT HOW INVERTER CONTROL CONSTANT CURRENT?

1944


What is the differance between 2 dc motors of armature voltage 660 v and 440 v?

1957


A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.

3033


A low wet bulb temperature indicates

1135


What is Phase to Phase clearance for 800V System Operating Voltage as per IEC61439

1010


at which voltage level arcing ground is occurs ??????????

2029


What should be the amps for a MV fuses for transformer 630kVA 20(10)/0.4 kV

2020


how we decide the require size is this for a known current at fuu load?

1939


How to connect the chemical earthing and complete process tell me plz

1849


if the number of poles generated in stator and rotor side of an induction motor are different then what will happen and why?

1866


How capacitor improves pf

1687


Explain the propagation of harmonics in the network and influence of phase angle of harmonics.

1947