Answer Posted / arun kumar
If it is a alarm ,as a member of ERT or Maintenance/management team,We should first analyse whether it is Real or false alarm by checking the fault zone indicated in the FA panel .It could be false alarm due to dust collection in detector or some other reason ,such case follow your organisation procedure and reset it ,'
If its a real fire and alarm ,do the possibility with you like if we are ERT member or trained ,inform first your seniors and Paralaly try to extinguish the fire with Extinguisher/Hydrant system and also switch OFF the Power supply . Operate the MCP ,so others you can make alert and announce in PA system about the fire and to Evacuate the Building .
If you are not having any knowledge of Fire system ,first you evacuate the building and inform management for the proper action .
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Why Stabilising Resistor used in REF circuit ?
operation of protection relay watchdog contact?
why fractional pitch winding generally used in alternators?
salam&hi, i need to know about how can i calculate an enough current for the new building before i submit it to the suppliers
which connection is safer series or parallel?usually which connection we prefer at home?
Under wat condition statcom operates as an inductor for the transmission line?
Explain how you decide what size of electrical wire do you need?
What should be the length of transmission line so that we can see/obtain the full sine wave of voltage??
plz send me HPCL apptitude paper.. maulik_elect@yahoo.co.in
how will calculate the safe starting current of 3-phase squirrel cage induction motor?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Earth leakage relay basic knowledge principle
what is the difference b/w ground & virtual ground?
What is BusBar integrity test and how it is conducted?
HOW MANY TYPES OF FUSE?