Why Pressure Transmitter is NOT installed before up-stream of an ORIFICE PLATE? in a flow measurement.

Answer Posted / uttiya hazra

Pressure transmitter is not installed before up-stream of an orifice plate because in the region of up-stream there exists a pressure differential or pressure gradient.

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hi my name is rakesh patel i just complited my be in instrumentation & control now i am going to working as a validation engineer in a poject department so what is a scope in a future as a validation engginer ? what line is good for me can any bady give me complete solution please? your regard rakesh patel

1520


What is the procedure of calibration of Load cell?

1494


OBJECTIVE TYPE QUESTIONS OF ANALYTICAL INSTRUMENTATION

10298


what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration

1565


find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s

1465






How to find out the current of two motors having same power consumption but different RPM?

1542


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

1638


can you provide me full detail about instrumentation in ONGC??

1754


If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?

1832


explain key exchanges in all security modes WPA,WPA2,TLS?

1497


what different types of problems do occur while doing instrumentation commisioning and how to solve them? please explain in detail

1323


we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.

1286


how to measure draft pressure in transmitter pl. give its single line digram

1526


how to tune siemens sipart electro pneumatic positioner..plz tel me..

1662


how will you segregate the alarm levels in alarm management system during factory Acceptance Test

1928