Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why Transformer and DG rating capacity is in KVA

Answer Posted / muthuvel

Actually Dg and Transformer Supplying Apparent power only . At the load point only power is segregated by real and reactive power.The Apparent power measured by the unit of kVA(Kilo Volt Ampere),the True power measured by the unit of KW,the reactive power measured by the unit of kVAR(Kilo volt ampere with reactive component).For that reason only DG and Transformer ratings are in KVA.

Is This Answer Correct ?    4 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why neutral is not used in three phases dol starter

1954


What is servo motor and what are different types of servo motor

2400


Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards

2097


explain the mode of metal iranafer in Co,welding

1590


Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?

2041


Differentiate between ideal and non-ideal voltage sources?

1088


what is the use of permanent magnet generator in exciter

2168


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

2012


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2156


Is RTCC panel needs any control supply.

2056


What is difference between Over Current & Earth Fault protection?

2446


sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance

2100


define the non synchoronism of synchoronous machine in general g or m??

1873


please tell me how a surge protector work on a DC 48Volt.? please describe briefly.

1847


which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?

2188