why buchholz relay installed in inclined position
Answer Posted / alok singh
Buchholz relay is installed in inclined position because of its function as it is used for internal fault protection inside the transformer as in case of over heating and loading of transformer oil temperature also increases hence oil expands inside the body of transformer so that excessive oil expands during heating or time of fault enters in buchholz relays body and after a particular level relays coil get trips and gives an alarm to the operator regarding the fault.
| Is This Answer Correct ? | 3 Yes | 3 No |
Post New Answer View All Answers
A 3-phase IM is supplied from 50 Hz system. It runs at speed of 1440 rpm and slip equal to 4 %. Calculate number of pole pairs. A 1 B 6 C 2 D 3
In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?
WHAT IS VCB SAFETY
can we do the star delta connection of capacitor for 3- phase motor starter.
why we can use 1 to 5V dc
In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?
As a electrical engineer.. what are the basic norms should follow in transformer oil testing.. 1.What is the Electrode type? 2.How long time you will give for oil testing?
i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.
what will happen if synchronous machine rotor fed from single phase ac supply
sir iam a 3rd yr eee student.no core company comes for recruitment to our college.my aim is to be placed in l and t.tell me the procedures.
Define steady state error.
Why the dc voltage drop during starting of emergency lube oil pump? The Voltage drop from 135kv to 125 kv for one min. before re-establish to 135kv?
what is the difference between circular wdg & ractangular wdg?