what is the Difference Between Domain and Station?
Answer Posted / praven kumar m
In Yokogawa System if the no. of station is 56 or less than
56 the domain no, will be domain#1. If it exceeds more than
56 stations then we have to consider 2 domains (i.e.,
domain#1 and domain#2)
For eg. if there are 2 units, and the first unit consists
of 65 stations. in this case the first 56 stations will be
considered as domain#1 and station nos. from 57 to 65 will
be considered as domain#2. The 2nd unit will be considered
as domain#3.
| Is This Answer Correct ? | 1 Yes | 4 No |
Post New Answer View All Answers
What are the materials available to prepare individually for competetive exams in Instrumentation field? Plz reply...
hello sir/madam, I,Subramanian need 5yrs placement papers of officer trainee of Instrumentation technology.pls send to this mail id mani_nxtgen@yahoo.co.in please do the needful. with regards, subramanian.v
the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)
Q-Explain the different load conditions that will produced different offset which may or may not be acceptable to thhe control function
what is the calibration procedure for magnetic flow meter @ onsite
How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer
what is piezoelectric transducer?give an example in power plant n state its principle?
How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?
What is sensitivity in vibration probes..?
Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?
PLEASE PROVIDE SAMPLES OF CHEVRON SKILL TESTS
If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?
What is hp & mp seperator .& what is its working principle ?
Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.
What are different type of instrument cable