Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is difference b/w fuse and breaker?

Answer Posted / chreamz

A fuse is a normally closed protective device that ionises
(burnout open circuitry) under fault condition or when
current over its rating flow through it. Everything happens
automatically with no external actuator. Once blown, it
must be replaced. A circuit breaker if also a protective
device that gets a closing/tripping command from the relay.
It has internal & external devices (actuator) that bring
about execute the action sent by the relay. The life span
of the CB depends on the load, operation and maintenance.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

SUTIABLE FOR ohm's law super conductor

1926


Why armature rheostat is kept in maximum position?

1087


how withstand of hi-pot test outputs of transformer wire 2.5mm

1948


How to test IR testing & magnetic balance test

1982


What is the function of probe in cro?

1178


what & how to check the lightning arrester

1892


Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC

2093


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2135


why we change the direction of winding in rotor ?how we make the north and south pole?

2033


When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number

2145


What is the difference between rulling span and wind span of of an Over Head Transmission Line?

2310


what is arc flash and what are the hazards involved

2139


what is Fault level? why it is calculated? how will u decide same for our plant?

2031


For R-L or R-C ckt,time constant formula is L/R and RC respectively and its unit is in sec.Pls tell me the derivation

3259


Please define ampere?

1099