CAN WE CALIBRATE LEVEL TRANSMITTER USING HART
COMMUNICATOR WHEN WATER LEVEL IS PRESENT IN THE BOILER
SHELL?
Answer Posted / haparmar
Yes we can calibrate through Hart But care should be taken
that Drum level should be controlled
| Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
what is performance test.need defination
I have 0.75mm sq multicore cable (IS type) , can use instead of same type but 1.5 sq mm cable ? Note : The distance is around about 150 meter.
send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com
How to calibrate Magnetic flow Transmitter in Field
why any measurement made interms of pressure is more accurate ? to be more precise most of the flow velocity is made interms of pressure and it is accurate. what is the reason behind pressure measurement being accurate ?
can you provide me full detail about instrumentation in ONGC??
How can a d.p. Transmitter be calibrated?
what is difference between fork type and capacitance type level switch. where it is using
what are the steps I have to deal with?
What is the use of temprature compensation?
When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.
Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
control panel design guidelines
What is the purpose of bypass valve across AS valve.