In an LT pole, the line voltage is 415V. How is it
converted to 230V into the house via the service cable?
Answer Posted / kaushal
From distrubation transformer we get three phases and one
netural (due to Star connection) these four wire(three
phases and one netural)are layed over head on LT poles and
for house only one phase along with netural is used and no
convertor is used as phase to netural voltage is 230volt
between R -y- b phase voltages are 415 - 415-415 called
as line value where as between phase and neutral it will
be 415/1.732 = 239 approximately 230v called as phase value
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
What is synchro?
0.5,1,1.5,2.5,4.0.6.0,10,16 square mm electrical wires how much take maximum current in 50htz
Hi guys! Plz help me to answer the following questions. 1. What are the types of transmission line energy losses? 2. Why are the VLF are used some types of services? 3. What frequencies are used for reliable beyond the horizon terrestrial communication without repeaters? 4. To permit selection of 1 out 16 equi-probable, what is the number of bitis required? 5. What is the most common modulation used for telegraphy? 6. What is the multiplexing is used to increase the capacity of the optic fiber? Thanks
Earth is a conductor or load?then ammeter connect to 3- phase supply,it shows the measurents or not?
PAC and simple Ac different
How to calculate the no of Ceiling fan (1200mm sweep) per unit area?
please send me last 5 year interview questions
What test must you do before powering up a circuit that you have been working on?
define the non synchoronism of synchoronous machine in general g or m??
If a surge divertor is required to be protected by 32 amp C Curve Circuit breaker does this limit the amount of protection from surges that you will acheive
Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
What is shunt voltage and u v voltage witch one best
Can Anyone Answer anyone of these ? Q1) why direct SOLUTION of Load Flow Studies in Not Possile ? Q2)Why majority of Buses in power system are load buses Q3)Why one of the buses in Power system is taken as reference bus (slack or swing) Bus ? Q4)Bus Admittance Matrix is a sparce (means it contains some zero elements ) matrix , give reason
What id difference between power and energy?