Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the difference between protection class CT and
Class PS CT

Answer Posted / vikas

The main difference between Protection Class CT and Class
PS CT is the accuracy level. Accuracy level of a Protection
class CT is higher then that of PS class.

Both Protection class as well as PS class can be used in
both metering as well as in Protection Purpose, depends
upon the criticality of the protection. But generally
Protection class CT is used for Protection purpose whereas
PS class CT is used for Metering purpose (in India).

In foreign projects, only Protection class CT's are used,
no PS class CT is there.

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

The Howland current source produces a A Unidirectional floating load current B Bidirectional single-ended load current C Unidirectional single-ended load current D Bidirectional floating load current

2070


I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....

2057


Why GRR starts from 60% of motor speed why not less than 60%?

1683


why dc is used in control circuit for mv & hv switchgear instead of ac

1904


What is a fuse? How does it work? What are materials used?

2010


what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors

1987


why normally Generator rating are between 11Kv to 22Kv?

4626


What are locations arc protection relay is fixed.

1850


Why dry type cast resin transformers tap link blast in HV side while power shut down times on load?

2306


TO CALCULATE THE RESISTANCE OF GRR OF HT MOTOR 400KW WHEREAS STATOR VOLTAGE 6.6KV AND ROTOR VOLTAGE 705V AND ROTOR CURRENT IS 346A.

5476


why T/F winding temp measurement cts are odd secondary current ie,109A/1.2A/1.4A?

1855


Why is tan-delta test and capacitor measurement done on alternator?

2193


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating

2393


does a DG set has low fault level as compared to that of a transformer.If yes then why.

1961


Wind mill

1861