Answer Posted / vamsi krishna
EVERY SYSTEM HAS ITS RESPONSE AS 1) TRANSIENT RESPONSE AND
2) STEADY STATE RESPONSE
TRANSIENT STATE IN A SYSTEM IS THAT WHICH OCCURS FOR A
MILLI SECONDS DURATION OF TIME. IT IS ACTUALLY OCCURENED
DUE TO DIFFERENT CAUSES AS
1) SUDDEN ENERGISING OF THE SYSTEM.
2) LOADING THE SYSTEM SUDDENLY.
3) WHEN SYSTEM IS TERMINATED WITH THE NON CHARACTERISTIC
IMPEADENCE....ETC
THE MAIN REASON FOR THE TRANSIENTS IS THE PRESENCE AND
EFFECT OF ENERGY STORAGE ELECMENTS IN THE SYSTEM.
THERE ARE A NUMEROUS WAYS OF SOLVING METHODS FOR TRANSIENT
STABILITY.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
wat is d diffr btw shunt coil and trip coil in VCB?
How the circuit breaker is selected for Induction motor of 100 kW, 415 volt, 0.85 power factor, 0.95 efficiency ?
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
Define conversion efficiency of a power amplifier.
hi guys please tell me the procedure for mesuring the coil resistance of 3ph induction motor?
HOW MANY TYPES OF FUSE?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
What Maximam Gap Taibaar & Bush
What is the working principle of servo motor? And explain it.
would you please give me any idea about the BARC interview question on electrical? i have an interview on 1st july.....plz hlp me.......its urgent......
how to calculate fuse rating for a motor
what is the criterion for selecting vector group of Transformers ? i mean how to decide vector group of Generator transformer, substation trasformer and transformer at consumer end
Explain about 3 phase motor fault current calculation with examples?
what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY
What is the dc grounding system and what is diff between AC/DC grounding system?