Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I am working on a 11KV system with fault current of 40KA
for 1 second. I have selected 2500MVA 11/0.433KV
transformer.
How can i find the impedance value for this transformer?
Please help me.

Answer Posted / wareagle

First I do not believe an 11 kv system can have a 40ka
fault. You need to check again.
Second I do not believe you can connect a 2500 mva
transformer to an 11 kv system. Maybe 2500 kva.
%Impedance is on the nameplate of the transformer or ask
the manufacturer.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is shunt voltage and u v voltage witch one best

1768


I need the recommended size for a 3 phase transformer at 13.8 KV Primary and connected loads of 3000 kVA at 4200 volts and 2375 kVA @ 480 volts AC.

2077


1sq mm dc powr cable can carry how much dc currnt

2146


WHAT IS THE DIFFERENCE BETWEEN GENERAL INVERTER AND SOLOR INVERTER TELL ME PLZ

2249


What are the characteristics of negative feedback?

1116


How to calculate or formula to calculate rhe power in 2 phase system ??

1551


state the working principle of incondenscent tube?

1984


WHICH SIZE A.B.CABLE IS USED FOR 11KV.

2252


WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?

2175


How to use computer cpu ups use for home inverter circuit board

1834


HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?

2676


what are the installation procedure of high voltage power transformer,CT,CB&PT?

2122


What are protections for dty type transformers

1883


how line turns ratio changes in 3 phase with change in connection

2020


Minimum IR value of 1.1 kv grade 3.5c (300, 240,185,150,120,95,70,50,35,25) sqmm Aluminium XLPE cable and 4c (16, 10,6 & 4) sqmm cu arm cable between RY,YB,BR,RN,YN,BN,RE,YE,BE & NE.

3398