what is the procedure to isolate flow a transmitter and
flushing it?
Answer Posted / suresh agravat
First close root valve
second isolate manifold valve
open equaliser valve it was zero check procedure
open root valve
open manifold isolated valve
close equaliser valve it was taken in line procedure.
| Is This Answer Correct ? | 0 Yes | 8 No |
Post New Answer View All Answers
What is the procedure of calibration of Load cell?
How to calibrate H2s Dectector
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
hye SAM acn u send your e mail id, so that i can solve my query through e mail?
Isometric drawings are generated during _________________ phase of a project
we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.
please send me some question papers of HPCL aptitude test ?? please send it to bipinb.28@gmail.com ...
What is the function of solenoid valve in on/off & shutdown valve and why it is not used in control valve normally?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
what is the importance of CV in the control valves? how it is calculated?
you are on site,the plant trips,you are approached by operations,what do you do?
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s
how to commission furnace ( water heater)
i want to know the interview format fot gail, instrumentation. pls answer me in habib.sami1003@gmail.com