How can decide the MVA rating of power transformer for
substation like 220/132, 132/66, 66/33kv etc or even higher
kv rating of substation????
Send me the strictly technical answer that shows your strong
technical aptitude.

Answer Posted / milinda4p

The MVA rating of a power transformer depends on the load
connected to the transformers. this can be calculated (for a
grid transformer) by calculating the total MVA of the
primary substation transformers connected to it.Generally
this is calculated with a extra space for load connection.

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between electronic regulator and ordinary electrical rheostat regulator for fans?

637


How to discuss the phase shift of transformer considering open delta?

955


what may the reason for vector shift in a generator?

1384


What are the advantages and disadvantages of negative feed back?

628


could you measure current in parallel?

671






how to control dc motor?

1406


in basic 2 phase will short means tripping the power but spot welding 2 phase shorting but not tripping it will welded why.....(Q)

1491


What is the IS standard for MCCB to be use (As per capacity of AMP)& for ACB also.

1565


give me a clear defination of inductance,and how can u calculate inductance of a motor

2309


If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.

1460


Name the component u would expect to find in a switchgear assembly?

1573


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1397


What is a DC series motor?

704


How to findout raw or ups power? its not indicated in socket,

1530


What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA

1146