Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why pneumatic control signal output is use 0.2 to 1 kg/cm2

Answer Posted / rana mujahid

starting from .2 is for live zero and .2 to 1 kg/cm2 is
because in this range the relation b/w flapper and nozzal
movment is linear,it was observed in starting of pneumatic
instrument after this it became standard....and still now
contineu

Is This Answer Correct ?    6 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i have steam drum height 1000mm. and i want to placed the transmitter below the tap.how i calculate.

2064


Why do we floating DC in DC system.

2883


what would be the minimum flow rate that we can measure on rotameter..?

2074


Please any one can provide latest aptitude test,technical test and interview questions for tata consulting engineering (TCE) i need it asap thanks in advance

1999


what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d

5350


what is orfics working in main steam line. is it increase pressure, velocity of steam flow and dicrease steam flow rate. or any other

2165


whatis range of marcury filled tempereture gague

1932


How hart protocol can be connected with control valves?

1028


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

2190


How does temperature bath work? How does coil gets heated only by applying some current?

1807


in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.

2790


flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty

2288


How to calibrate the flow transmitter

1597


How addressable fire systems work? Pl. send details with architect.(Loop), also send details regarding Gas system. Pl. help me.Thanks

2086


How will you calibrate an Absolute Pr.Transmitter of range 400mmHg absolute ?

2023