why we use 110vac in overhead crains? why not 220v, 24v
Answer Posted / manuel philip chennai
Control voltages only control the entire operation of the
crane or machine.operating voltage will be hire. if we use
low control voltage it is safe for the person who is
operating the equipment. For control pendent push buttons
only control voltage is supplied,if there is earth fault the
pendent operator will not get heavy shock. there are other
control voltage like 24,48 volts also used in machine tools
and other equipments. it is for only the safety condition of
the operator low voltage is used.
| Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
Explain about 3 phase motor fault current calculation with examples?
i m electrical diploma holder i want to do plc $ Scada some body tell me which insitute is best for me near chandigarh
In India the supply voltage is 230 volt A.C. During the negative half cycle phase becomes neutral and neutral become phase? or what will happen during negative half cycle? how the electrons flow during positive and negative half cycle?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?
How to address the servo drive for motor
How to select the cable and voltage drop in circuit?
How does zener phenomenon differ from avalanche breakdown?
if we give 60 hz single phase supply to the transformer used in europe , than what will happen
How to test REF relay testing for LV panel as per Kahramaa standard?
i have to install a HT panel, what components, I have to use in this and what will the diagram of that diagram,please tell me each and everything.
how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment
What will be result if we connect LT votage to the terminal of HT motor?
Either It Possible a dc Motor to Run On Ac Drive [ Ex : ACS 800 , Yaskawa F7 ] If it is Possible How Pls Inform Me dinesh_elect_eng@yahoo.com
thyristor controlled APFC panel design parameter?