Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is trip circuit supervision relay? How does it work in
switchgear?

Answer Posted / hanuman

trip circuit supervision relay is the relay which
supervises the trip circuit of the circuit breaker. It even
tests wheather dc supply to trip circuit is under proper
condition or not. some times trip circuit gives signal to
circuit breaker, but circuit breaker doesn't break the
circuit, then supervision relay makes circuit to break by
LBB.

Is This Answer Correct ?    19 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is difference between isolation and ultra isolation transformer?, what is the method of testing ?

4308


CAN CU XLPE/PVC CABLE BE USED INPLACE OF LOW NOISE SCREENED CABLE? KINDLY GIVE REASONS

1861


We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

1962


In dc ckt. 24v or 110v, which one is more efficient and why?

2221


Why field rheostat is kept in minimum position while armature rheostat at maximum position?

1091


how we can do the insulation on secondary of ct explain and so that tan delta will within limit

1904


How to calculate VA rating for CT or PT or Control Transformer?

2834


Mention what are the different colors on wires indicates?

1245


What is Delta Connection? What is meant by Forward Delta & Reverse Delta & How Will be the Connection in Power Transformers?

2255


what is the effect of change in supply frequency on load angle of synchronous motor,all other parameters remaining same?

2334


In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)

1753


what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY

2190


How to determine stage of Automatic Power factor controlling Relay(Apfcr)?

2149


please tell me when we start motor without load in star or delta connection whose current above condition,pl write formula

2280


What we mean by vintage of an engine+Generator?

2101