Answer Posted / pradhyumn
Ideal Power factor is 1.
It is ratio of real power(measured in watts) flowing to the
load to apparent power(measured in VA). It ranges between 0
to 1.
P.F. is a measure of the degree to which a given load
matches to that of a pure resistance.
P.F.=1 if load is purely resistive.
P.F.=0 if load is inductive or capacitive or both.
For RL-circuit P.F. is between 0&1.(lagging)
For RC-circuit P.F. is between 0&1.(leading).
| Is This Answer Correct ? | 8 Yes | 0 No |
Post New Answer View All Answers
Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,
what is difference between cpp electrical system and refinery electrical system
can anyone tell me can the electromagnetic waves can be reflected back?if so how &by which material it can be reflected back?please tell me so that it can help to my wireless power trasnmission device.
how we design a pannel to start 10HP motor with the help of star delta starter?
What is the most important precaution in any experiment with d.c. Shunt motor?
How much load can take a 16 mm aluminum cable 3 phase
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.
what is magnetizing current test in power transformer
WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?
What is sink and source?
In an ACB shunt trip coil and undervoltage coil operated normally( breaker open and charged). But closing coil not operating untill manually discharge and recharging. Any help.
how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids
where is the need for short circuit test for 3 see is required and why? can you explain in brief with application
is it necessary to earth the rmu before cutting off the transformer winding?if yes why?