what is threshold voltage for a relay???what does it
exactly means ?whats its value in our indian transmission
system say 11kv feeder RMU relay
Answer Posted / ritesh jaiswal
Threshold value of relay provide lower and upper operating voltage,if nominal operating voltage of relay is 24v and threshold value is 50% of nominal voltage then lower operating voltage is 12v and upper operating voltage is 36v.
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
how to control the speed to switched reluctance motor
role of europe union in UK safety legistlation (electrical safety)
What is the use of mc( moving coil) in dc voltmeter and dc ammter and what is the use of ( moving iron)in ac voltmeter nd ac ammeter
what is invertor supply and raw powersupply
why on axial hitting up of air blast on hydrogen produced in oil circuit breaker,temperature rises of the core of the arc?
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
explain the process of commutation in a dc machine. Explain what are inter-poles and why they are required in a dc machine.
How to work definite,over pluxing,revers power,OSR relay
can we conduct the swineburne's test on a dc series motor? why?
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
what is POTT and PUTT explain?
I am an American living in Vietnam and I have recently gotten a refrigerator from Japan and it is rated for 100 vac, but the power here is 220 so I bought a voltage stabilizer it has a 1 kva output rating. Can you please tell me what the amperage is? I'm confused and without a working fridge.
The electromagnetic torque developed is proportional to what in a D.C series motor?
What if high voltage side circuit breaker of a ehv transformer instead of lvcb? Kindly elaborate.
Which type of DG need Netral Earthing?