Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

howmuch current can carry the 2.5Sqmm copper cable?

Answer Posted / bobcat_rob_ oman

For NEC 25 amps depending on waht kind, thW, THHN, TW PVC
IEC 23 amps

better see manufacturer's ampacity... this is the required
ampacity at normal ambient temperature 30degree celsius.

Now if you will installing this to a certain area... then
you must consider the correction factors such as ambient
temerature, distance of installation, type installation(
grouping factor, wall cavity installation, direct burial,
etc..) then you apply these correction factors.. and there!
you have the proper ampacity for a 2.5 sq. mm copper
wire....

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the disadvantages of thermal power plant?

1098


On what basis the the size of Lightning arrester for buildings are selected ?

1662


what is meant by twilight switches 7 where its applicable ?

1929


Draw the vector diagram and condition for the following: 1) Dyn1 2) Ynd0 3) YnYn0

3675


how we test a 3 phase motor on single phase supply....? HOW WE RUN A 3 PHASE MOTOR ON SNIGLE PHASE. supply for testing..? how we verify of a 3 phase motors 6 wire & name thame a1/a2/a3..b1/b2/b3 and c1/c2/c3 for connecting star delta starter ........i have only 1 phase supply ? help forum..........

5206


In the ACB breaker capacity is 2000Amp but this each phase taken 1250 But total beldibg load is 600amp or 700amp watt is the problem

1966


given data are load current & power factor cable core size? plz any one update the calculation formula

1904


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1806


what is the difference between RMS & TRUE RMS VOLTAGE

2962


where reactive power is used

2059


difference between high and low impedance BUS BAR relay??

1626


why are the maintaine power factor and how can this control and this is how work.

1983


What is difference between mcb and mccb.

1157


What is transmittance?

1134


difference between semiconductor & conductor & insulator?

2382