what do you mean by PF correction. A motor is rated at 15
kw,415 volts, 0.7 pf and eff of 0.92. The powerfactor is
improved to 0.98 by adding capacitors at the bus. calculate
the current drawn by motor under full load condition before
and after pf correction

Answer Posted / technicalarticlessbsvbsbsvb

No change. whatever was at rated pf will continue to be
drawn

Is This Answer Correct ?    2 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how a.c. genarator control power factor when its conected to grid supply by incrising or decresing excitation voltage.

2706


hello everybody. what does an abnormal stator winding impedance or dc resistance show? thanx

1476


what is the difference between vector scale and vector diagram?

3759


Why in 6 KV XLPE cable termination kit used and why not in 380 V xlpe cable same is not used

2201


where is core-type and shell-type construction suitable for transformers ?

1644






1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?

1685


What is the name of transformers oil filteration equipment?

1586


What is accuracy of a measurement?

711


What products have you designed which have entered high volume production?

1574


if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.

1571


Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?

1033


What is mean by Sensitive Earth fault & what are the effects

3744


I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

3514


When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?

1358


what is mean by kneepoint voltage? when it will happen? ( my doubt is, if CT secondary is open means ct get saturation or blas? what are factors are required for calculations? plz give currect anws:

1520