Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Hello friends., my question is related to testing of current
transformer... A Ct having knee point voltage of 750 volts.,
and I have two step up transformer's of rating 230 v to
440 volts., can I obtain the value of 750 volts by using the
two transformer's.... If yes then how could I connect the
transformer's to obtain knee point voltage?? thank you in
advance

Answer Posted / k.prakashchandra

Connect 230 V sides of trs in parallel with
dimmer-stat.Connect secondaries in series . Connections
should be done in such a way that the secondary voltages add
to each other.This can be ensured by measuring voltage .

Is This Answer Correct ?    1 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1878


How to test the Secure Elite 440 Multi function meter working condition.

2216


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

2018


why swityard is necessrry requirement in any bis power distributin systems?

2437


what is the voltage between earth to neutral in lift.

1871


can anyone send me some sample question regarding power grid corp

2251


sir, 3phase induction motor takes different pf and different KW in three phase while running,explain reason

1539


CALCULATE THE TOTAL VOLTAGE DROP AND SELECT THE CABLE SIZE IN MM-SQARE FOR A PANEL-262KW AT 110 METER FROM THE SOURCE SUPPLY , SUPPLY VOLTAGE 240/415

2721


7- What is the Dissipation Factor and the difference between it and Insulation Resistance Test? 8- What is the task (function) of DC and AC reactors in power plant? 9- What is the task (function) of (open delta with earthed) in some types in transformers? 10- What is the base of the selection of the vector group in transformers? 11- What is the zig-zag transformer and its function by drawing in large detail? 12- What is the polarity ? 13- Why we make short between phase(R) in high side and phase (r) in low side in vector group test? Where High Side ( R ,S and T ) and Low Side ( r ,s and t ). 14- What are the time on delay and time off delay? 15- What is the vector group? 15- What is the task (function) of different types of vector group such as Dyn11 , Dd0 , YNd1,……..,?

2325


1 Ton is equal to how many watts?

1171


how to carried out tan delta test in 11 KV alternator ?

3129


What will be the voltage regulation of a full load and 0.80 power factor lagging load transformer when a two winding single phase transformer has a voltage regulation of 4.5% at full load and unity power factor?

1285


What is inrush current? how can calculateit? what is the affect of it?

2107


why need to be maintain power factor for industrial customer?

5193


What is the difference between resistance grounding system and resistance earthing system?

1163