Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why rotor current reading is taken & why not stator?

Answer Posted / godwin

if the load increases also the current increases in the
rotor, if the current increases also the heat increase, heat
is a loss, heat increases the motor get damage, so the rotor
current reading is taken to the account.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between electronic regulator and ordinary rheostat regulator for fans?

1003


How to derive detailed design of Suitable bus Bar for 100A for 6.6KV?

1797


which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?

1961


Is potential difference materials property ..? if yes tnen how.. explain brifly.

2032


why we use ac supply as 415 volts instead of 415 v why we cant apply 230 v for dc

2387


what can be the causes of capacitor start motor having a higher current that its actual

1954


How to calculate Voltage regulation of 22 KV Over head Line.

1638


What is the meaning of dedicated earthing?

2138


what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?

1597


pls tell us AC plant are how do work and parts name with picture

1940


what are the Alarm, Trip & Safety equipment (Issues) present in Power Transformers pls Mail it to ashokbabunhce@gmail.com

1895


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9147


What are approaches to tackle sedimentation problem of reservoir?

1000


How to size Air Circuit breaker (ACB)? What is the most important factors?

2216


what is thresold of perception

2047