Answer Posted / naresh l patel
HT breaker is used to make or break HT supply. Breaker is
required to prevent arc during while breaking of supply.
| Is This Answer Correct ? | 27 Yes | 5 No |
Post New Answer View All Answers
What are the applications of different multistage amplifiers?Plz also write advantages of these amplifiers? Thaaaaaaaaanx
7- What is the Dissipation Factor and the difference between it and Insulation Resistance Test? 8- What is the task (function) of DC and AC reactors in power plant? 9- What is the task (function) of (open delta with earthed) in some types in transformers? 10- What is the base of the selection of the vector group in transformers? 11- What is the zig-zag transformer and its function by drawing in large detail? 12- What is the polarity ? 13- Why we make short between phase(R) in high side and phase (r) in low side in vector group test? Where High Side ( R ,S and T ) and Low Side ( r ,s and t ). 14- What are the time on delay and time off delay? 15- What is the vector group? 15- What is the task (function) of different types of vector group such as Dyn11 , Dd0 , YNd1,……..,?
how are reversing the direction of rotation of dc motor
Explain what is electric traction?
why incomer bay is required before transformer bay if there are more than 1 nos. of transformer bay.
What is the formuala to calculate the rating of motor protection circuit breaker
What are locations arc protection relay is fixed.
Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????
what is the meaning of 5% droop or 7% droop in AVR?
while starting a liquid starter ,is there any volage drop on water/soda on tank.can we touch the tank on starting?
How do we arrive at selecting reactive capacitance value as 30% of h.p rating of motor?
From reading, Under voltage relay used also as phase sequence relay now, Why I use under voltage and phase sequence relay in the same circuit (ATS)?
What is the de rating factor of cable? What is the importance of the de rating factor in cable select
Why does the rotor rotate?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.