What is RTCC panel and why it is required
Answer Posted / bibinck
RTCC means "Remote Tap Changer Control Cubicle". as the name
suggests it is used for remote operation. RTCC is used to
raise/lower the tap as and when required ,with the help of
an AVR-automatic voltage regulator,remotely . It also gives
important indications about the transformer such as oil temp
high, winding temp high , bucholz relay trip , coller fans
on/off. It gives a complete information of a transformer.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Discuss the effect of sudden loading of an induction motor
sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance
hi I have done 3 yrs diploma in electrical engg after 10+2. I have 16 years of work experience into design proposals sales and engg application development in LV/MV swithcgear and sub station automation field. I want to apply for immigration to new zealand but I am not sure whether I qualify or not since I dont have a degree. Can anyone advice? Thanks Riz
Hi,I am working in abroad for more than 3 years in a company operating with 11kv and 6.4 MW power. I need c licence in India,can I? some other says only i can get if i work for 2 years in india only! anybody kindly clarify by doubt.Thanks
There is air in a room . the top and bottom of the room are at constant temp. T1 and T2. DRAW THE temp profiles if a. T1 greater than T2 b. T1 less than T2
how to Select Lighting arrester? What r the parameters to be considered for the selection of Lighting arrester ?
can i use the six sigma method which is used in management area, in state estimation of power systems?
bsnl tta exam question
i have 3500 amp load and select current transformer and perches.how i calculate .please understand
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Explain what is electric traction? Explain few advantages of electric traction system?
what is the sludge current
The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason
what is the current density of copper & alluminium.
what is the meaning of osr in transformer.