Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is advantage in open delta connection?

Answer Posted / dwi tjahjono

Open delta connection (for PT as protection) usefull to detect the shifting voltage during normal and faulty condition.
We can use this to set the directional relay

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if we apply 1000ADC instead of 100ADC or We apply 50ADC instead of 100ADC,What will be happened in the test result value.Pl explain

1351


What is the difference between circuit breaker and isolator

1320


How to calculate KVA/VA rating of PT or CT from primary & secondary voltage or primary & secondary current?

2501


How to know th details about an electrical Drawing ? Please mention the easy method.

2496


defination of transistor controlled series capacitor

2684


Transformer diagram mention each parts ?

2092


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2198


draw 3 phase rectifier diagram

2260


What is the basic rule for block diagram reduction technique?

1327


BSNL TTA EXAM QUESTION

2221


how can you size an automatic voltage regulator?

2406


what is metering cum synchronizing panel and how it is used?

4711


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

2078


if the number of poles generated in stator and rotor side of an induction motor are different then what will happen and why?

1939


What is the simplest formula to calculate the rotor diameter of a synchronous generator?