400kw, 3.3Kv motor want to fix 1000km away from substation.
What is full load current? and what is the cable size for
motor? I amp expecting answer and advice from your side..
thanks...

Answer Posted / j.senthil kumar

Kindly confirm the application of motor, whether does it
require Drive?
If yes, you can add some external AC Choke to avoid the the
loss of power transmission.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is a fuse? How does it work? What are materials used?

1528


What is resistance reading of earth copper rod with grid and without grid?

648


What is dynamo?How it works and what is the function of dynamo in a DG.

1584


What does the term “voltage regulation” means?

631


how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets

1713






How to synchronization will be done between two DGs ?

1312


What is the best thing to protect the motor from running over full current. CT or O/L or pressure transducer at the given pressure rating

1022


why only exciting current is shown not primary current in transformer???

1392


in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com

2160


a starter used for squirrel cage induction motor?

1209


How 48-relay (incomplete sequence) functions?

3546


in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses?  the second question is-generation is depends on LV winding? or LV winding design for generation voltage?

1290


How to calculate cable size in HT AND LT

1508


what is the reactance,capacitance & impedence electrical armoured & unarmored Cables.

1624


What will happen if the d.c. Shunt motor opened accidentally running on no-load has its shunt field winding?

885