Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the current rating of 2500 KVA,33KV/433v transformer
on secondary(LT) side

Answer Posted / raj

input power= output power => transformer do's.

depends on ur load they will design.

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have motor of 3 H.P. How i found the rating of capacitor use in it in single phase motor..???

2638


Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not

1646


How to set the relay,,??

2101


What is an ideal transformer?

1179


How to calculate the current of Highpressure Mercury Vapour Lamp?what is the basis?whether we have to consider power factor or not?

2159


i need previous entrence exam papers of nhpc.

2845


what the function breaker failure scheme, how is it operated

1915


What is the actual meaning of thermal power efficiency ?

2178


2. Modify your design in question 1.a so that the circuit works according to the following function table X Y F 0 0 Clear 0 1 No Change 1 0 Parallel Loading 1 1 Count 3. Design a circuit that detects the pattern 010 in a serial input X considering: 3.a Overlapping 3.b No overlapping

1941


I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?

1966


On what basis the the size of Lightning arrester for buildings are selected ?

1660


Define load factor?

1128


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

1978


How to find out damper winding failure for synchronous machine?

1512


why don't we use the generator as a motor? and what will happen?