Answer Posted / siva
The Goerges phenomenon is the operation of a 3-phase wound-
rotor induction motor at half of synchronous speedand it is
obtained by unbalancing the rotor circuit. If the motor is
started with one rotor phase opened or with rotor
impedances greatly unbalanced, it will accelerate to half
speed and operate stably as a motor or generator.The motor
may be operated stably at half or full speed. The torque at
half speed is greater than at full speed, and may be almost
as great as the rated torque for a balanced rotor. It may
be desirable to operate an induction motor at half speed
intermittently or as a temporary measure. Disadvantages of
half speed operation are the low power factor, low pull-out
torque, the subfrequency line currents, and motor
vibrations.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is meant by Load Encroachment in OHL Feeder Protection?
Why we specify TNC switch with 1NO 1NC ,2NO 2NC ? how we get connection.?
how much UPS neutral erath leakage current.
What are the two types of compensation?
when the Transmission and Distribution network where is the "feeder" lines are located? and why should be used in T&D network.....
Explain the method to keep noises low in a control system?
For group 1 , 2 whather i have to prepare my technical or general studies etc? and im graduate in ee engg. for wht posts im eligible for? please tell me!
what are the ''pitting rings''and how cn they be controlled in a series generator
What mean by MLTP
what type of questions are asked and howmwny questions belong this catagory?
what is static frequency converter?what is the function...of sfc...?
What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation
why we permissive overreach in distance protection.where it is applicable to use in long r short lines
I completed my BE EEE degree 2006 .... which license should i apply .... ?????
the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?