what is lifespan of an RCC structure?
Why the RCC structures failing in quater of its life span?
Answer Posted / arun verma
When the RCC was developed in the early mid twentieth
century, the quality of each input was taken into account
based of the cost of inputs and the quality of our
integrity at that time.
With passage of time the quality of inputs have gone down,
One because of poor integrity of each of us contributing
into it be it the material manufacturer or the worker at
the workmanship stage.
and
Two because the cost of each thing be it labour or
material, has gone up substantially, compelling the
manufacturers and material suppliers to supply material at
competent rates, thereby prompting them to compromise in
quality.
Also while the factor of safety taken into account at time
was 3 X 3 times with plain mild steel, now with torsteel it
has been brought down presuming that the structures are
never stressed to that extent.
I believe, if we we are able to correct our mentality and
if the buyer agrees to pay the hike in the cost towards
improving the material quality and the workmanship, the
life will be atleast 80% of the stipulated life of 100
years.
Is This Answer Correct ? | 8 Yes | 3 No |
Post New Answer View All Answers
What is M40 _ TOR - EQ and B.F.S
what is w/c ratio in dry lean concrete for m10 mix design
what is the difference between np2 and np3 concrete mix
What are the applications of modulus of elasticity?
in a corner footing of a building, column lies in one corner. in this condition i want to know if the reactive pressure of soil will be uniformly distributed throughout the footing or will be uniformly varying as in the case of eccentrical loading.
for pretensioning which will yield first and same for post tensioning?
Explain what is progress payment?
Can inverted beams used in pipes during construction? If yes, explain how it can be implemented?
What is bylayer?
how to design and calculate materail quantity for concrete speedbreaker ?
what is Short bored pile foundation.
A doubly reinforced concrete beam is 25 cm wide and 50cm deep to the centre of tension reinforcement. The centre of compression is steel is 5cm from the compression edge. The areas of the compression and the tension steel are 10.16cm2 and 12.56 cm2 if m=18 and the bending moment at the section is 7,000,000 N-cm. Calculate the stress in concrete and steel.
What is a bearing capacity of soil?
What is meaning of Canceled/Flat Beam. What is difference between them? Both type of beam can bear same load if size (width)of the flat beam is increases and depth is same as slab thickness? Kindly suggest to me.
How many types bend used in civil reinforcing