what is lifespan of an RCC structure?
Why the RCC structures failing in quater of its life span?

Answer Posted / arun verma

When the RCC was developed in the early mid twentieth
century, the quality of each input was taken into account
based of the cost of inputs and the quality of our
integrity at that time.

With passage of time the quality of inputs have gone down,
One because of poor integrity of each of us contributing
into it be it the material manufacturer or the worker at
the workmanship stage.

and

Two because the cost of each thing be it labour or
material, has gone up substantially, compelling the
manufacturers and material suppliers to supply material at
competent rates, thereby prompting them to compromise in
quality.
Also while the factor of safety taken into account at time
was 3 X 3 times with plain mild steel, now with torsteel it
has been brought down presuming that the structures are
never stressed to that extent.

I believe, if we we are able to correct our mentality and
if the buyer agrees to pay the hike in the cost towards
improving the material quality and the workmanship, the
life will be atleast 80% of the stipulated life of 100
years.

Is This Answer Correct ?    8 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is M40 _ TOR - EQ and B.F.S

2021


what is w/c ratio in dry lean concrete for m10 mix design

7978


what is the difference between np2 and np3 concrete mix

1557


What are the applications of modulus of elasticity?

762


in a corner footing of a building, column lies in one corner. in this condition i want to know if the reactive pressure of soil will be uniformly distributed throughout the footing or will be uniformly varying as in the case of eccentrical loading.

1723






for pretensioning which will yield first and same for post tensioning?

1711


Explain what is progress payment?

707


Can inverted beams used in pipes during construction? If yes, explain how it can be implemented?

884


What is bylayer?

682


how to design and calculate materail quantity for concrete speedbreaker ?

5377


what is Short bored pile foundation.

2197


A doubly reinforced concrete beam is 25 cm wide and 50cm deep to the centre of tension reinforcement. The centre of compression is steel is 5cm from the compression edge. The areas of the compression and the tension steel are 10.16cm2 and 12.56 cm2 if m=18 and the bending moment at the section is 7,000,000 N-cm. Calculate the stress in concrete and steel.

1715


What is a bearing capacity of soil?

811


What is meaning of Canceled/Flat Beam. What is difference between them? Both type of beam can bear same load if size (width)of the flat beam is increases and depth is same as slab thickness? Kindly suggest to me.

1849


How many types bend used in civil reinforcing

2779