Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why power generated only 11KV not more than????????
and why power up/down is multification of 11*?=??.???
foe Example 11/33,11/66,66/11KV etc,

Answer Posted / dkverma67

AS insulation of alternator winding is comparatively easy & economical at 11KV.
Voltage rating is always multiple of 1.1 or 11 due to form factor. EMF induced in alternator is E(max.) value. The average value of induced EMF =Emaximum x 1.11.Here 1.11 is farm factor.

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what work will do diffrential realay DG set

2882


12.5 tons a/c is their how much kva generator can recommend to the customer.

2018


For an induction motor wat is the loading/unloading cycle duration or interms of L/UL ratio/ percentage?

2094


Do closed loops systems require manual input?

1196


how many load we can take for lighting

2265


how to deside the capacity of chock for drive?

2048


WILL SCHNEIDER MAKE ACB(MASTERPACT)TRIP ON REVERSE POWER?

2215


Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,

1633


what is the prinsiple of dc motor and construction and working ,application of dc motor.

1953


What is limitedly stable system?

1113


Whether IP65 enclosure box blocks ventilation if driver for LED have to enclosed inside IP65 box

2075


DRAW ACIRCUIT DIAGRAM OF 100 KVA 415V/55-0-55V DELTA TO STAR TRANSFORMER

2038


Why CBCT rating is 50/1A

2848


What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)

2156


1.Can we use 6.6/11KV 300sq mm xlpe 3core cable for LT use (415 Volt). 2. If we use it for LT then what is the current rating

1759