why DG,Transformer,UPS capacity will be tell in KVA but not
in KW?
Answer Posted / v.singaravel
Copper loss depending upon the voltage .core loss depeon
the current. both the lossse are meassure in voltage and
current thats why we are mensione in KVA .
| Is This Answer Correct ? | 7 Yes | 3 No |
Post New Answer View All Answers
what transformer we used normally and upto which kva?
how to protect motor in dol starter having capacity of 30 hp.40 hp?
What is difference between Over Current & Earth Fault protection?
how can i get the formula to find out the cable size if i know the load of main fuse protection.
Explain Even and Odd signals?
What current position are you holding in your current company?
Why you are switching off arc protection mcb when you are taking shutdown for lv board.
what is the difference between linear choke and suction choke?
is there any current and voltage drop on liquid resistance starter water/soda tank ?
wish of these transformer uses oil?
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
at work i have a genertor/alternater what is the easyest way to work out if it is dc or ac?
I am having dual speed motor of cromton greaves make of 3.7 KW -1400 rpm and 5 KW - 900 rpm. Please let me know groups and winding connction for rewinding purpose.
when will be the iocl interview results ifaced the interview on september 8 th
Generation of voltage for each phase are same of a turbogenerator.Although the short circuit current flow when two phase of turbogenerator are shorted(where current can't flow without potential difference),why?