how will you calculate rated Primary and Secondary voltage and
Current for 2500 KVA, 11kv/443V Transformer
Answer Posted / amit bose
primary I =(2500*1000)/(11*1000)
Secondary I= (2500*1000)/443
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
As an electrical engineer what are the responsibilities which i can hold in TCS?
why ht motors are star connected?
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
How to set a Zone 1 distance relay for distribution feeder?
sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com
if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .
define hysteresis loss, eddy current loss and windage loss
How to calculate Grid rotor resistance(GRR) losses in slip ring induction motor?
How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.
wat is the first thing dat is needed, 2 lay a cable in some area??
How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
what can be the causes of capacitor start motor having a higher current that its actual
bus bar design conditions and sizing pls tell me quickly
Explain marx circuit.