Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

hay friends, i am in trouble to understand PID controller.
several times i have study but it is not clear to me have
you a simple way to understand.

Answer Posted / yashwant

SEE THE SIMPLEST WAY WILL BE DEPEND ON YOUR REQUIREMENT OF
PROCESS, WHETHER YOU WANT SLOW OR FAST RESPONSE AND ACCURACY
YOU WISH. P VALUE FASTEN AND SLOW DOWN PROCESS, IF YOU REDUCE
VALUE OF P LESS THAN 1 PROCESS WILL BE ACTING VERY SLOW AND
ACCURACY ALSO WILL BE GOOD, AND IF IT IS MORE THAN 1 SYSTEM
ACTS SOME WHAT FAST AND FORWARD O/P IS EXPECTED.
I VALUE DECIDE THE SPAN AND SPEED WHILE REACHING SP AND AWAY
FROM SP. D IS USED FOR VERY FAST RESPONSE IE ON OR OFF VERY
FAST ACTION IT IS USED VERY RARELY AS PER PROCESS REQUIREMENT

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have energy meter for educational project having 0.5s class but my friend need 0.2s class meter , which one is good for that purpose and what is the actual difference of that two classes , need very easy example also.??

1392


What is 3 element control system

1475


how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr

7911


where proximity sensor installed on tank in loading arm application

1932


how to relay switch sense the fault?

2591


Please any one can provide latest aptitude test,technical test and interview questions for tata consulting engineering (TCE) i need it asap thanks in advance

2002


HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?

3503


the 3 most common transmitter protocol being in refinery or qatar gas and aramco.

2923


dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.

1869


What is hp & mp seperator .& what is its working principle ?

2221


What are the type of bonnets in the control valves?

1846


in which principle pressure tx,level tx ,flow tx,temp tx ,control valve works?

3149


how the arrangement of equipments done in control room

1993


in valve is constructed as per SME B 16.34, then which standard is used for fire testing of valve?.

2009


what is easiest way to read STL language in PLC?

3119