Answer Posted / anugrah nagar
LCN:It is called as Local control network.it is based on
Token passing Technology.Its speed is 5MBPS.LCN is used for
connect the system Network like PC,server with the help of
MAU assembly or etc.
UCN:-It is called as Universal control network.it is based
on Token passing Technology.Its speed is 5MBPS.UCN is used
for connect the Process Network like DCS,PlC Controller etc
with the help of UCN TAP assembly with the help of RG-6
coaxial cable(Drop Cable) or RG-11 coaxial cable(Trunk
Cable).RG-56 cable is used to connect NIM TO ucn CONTROL
NETWORK
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
SOME OF YOUR QUESTIONS ARE NOT MAKING ANY SENSE SO TRY AND PUT IN A LITTLE BIT MORE EFFORT BEFORE YOU POST A QUESTION. WE WILL ONLY HELP THOSE WHO WE CAN SEE ARE TRYING TO HELP THEMSELVES.
List three types Level Gauges with their working principles
I faced several time siemens ps2 positioner automatically getting Chang in it's set point direction after auto calibration So is there any causes biside this or any permissives ?
Why is the orifice tab provided?
Somebody can explain me about >Critical Loops, calibrations, ESD critical Loop checks, Logic Diagram / Cause & Effect checks for ESD loops,
If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?
Can I calibrate the Electromagnetic Flow Meter on line and How.
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
How to Calibrate Ultrasonic Level Transmitter in field
How to check vortex flow meter is in good condition while we do not having calibration setup?
what is actual drum level and compensated drum level?
Can any body tell me about SAP MAINTINANCE MODULE. WHAT IS its function and application. And study material Source about it. I shall be very thankful.
Can anybody tell me how to select the size of earthing cable for DCS & PLC system.Please tell me any relevant answer here or mail it to me.
Conversions
how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)