we have consol make 3 phase servo stabilizer for cnc m/c.
while installing the earth neutral voltage is 1.7 volts at
stbilizer off condition and when stabilizer get on en
voltage reaches 4.8 volts (new earthing is done and neutral
is helthy condition all phase to neutral volts 440,442,441
v)why this happen.solution for cause.
Answer Posted / k.prakashchandra
There is a slight loose connection/joint in the neutral wire
if the line voltages are equal.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.
why we use condenser in the thermal power plant, althrough the same vapour will be again heated
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
How to setting the volume of RTCC panel AVR (11kv) controller
In single phase ac ups supply when current is measured with tong tester neutral current is found more than phase current.What is the reason?
the typical output of a solar cell is........
what type of earthing do for dry fissure rock?
What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer
what are the values of VRY,VYB,VBR,Vry,Vyb,Vbr,Vrn,Vyn,Vbn for Magenetic balance test of 100 KVA and 63 KVA Distribution transformer
1. What is maximum permissible distance between smoke detectors ? 2. How do we decide number of smoke detectors required in a large office, warehouse, hall etc ? 3. What should be maximum height of smoke detectors ? 4. Where do we use heat detector, optical smoke detector, temperature sensitive detector ?
Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir
Is there any relevant technique to produce power from light and heat energy of the sun simultaneosly from same rays of light?
How to detect voltage vector shifting in interconnection protection.
i have attended the interview on 4th June,08 at Kolkata in IOCL, can anybody tell me what is its result