difference between isolator and circuit breaker?????
Answer Posted / suresh
You cant open a Isolator under load, while CB can be.
| Is This Answer Correct ? | 14 Yes | 2 No |
Post New Answer View All Answers
Why magnetic flux produces an induced current?? what is the detailed procedure ?? ans plz
Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method
what is the basic construction diffrance between servo motor ans sqiralcage induction motor
battery capacity use of made?
HOW TO CALCULATE THE VT SIZING?
how to carried out tan delta test in 11 KV alternator ?
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
UG cable sizes were specified in sqmm. But practically its not coming to mesure. What's the reason for that? And how they specify the size of the cable?
What do you mean by lighting transformer?
54 Comments Alok and Bhanu play the following min-max game. Given the expression N = 38 + X*(Y – Z) where X, Y and Z are variables representing single digits (0 to 9), Alok would like to maximize N while Bhanu would like to minimize it. Towards this end, Alok chooses a single digit number and Bhanu substitutes this for a variable of her choice (X, Y or Z). Alok then chooses the next value and Bhanu, the variable to substitute the value. Finally Alok proposes the value for the remaining variable. Assuming both play to their optimal strategies, the value of N at the end of the game would be?
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
Is phenomenon of resonance is harmfull fr the machine? if not or if yes please explain it?
what is the benefit of floating our DC source? if i have two floating DC source of which 1 has a ref voltage of -21VDC and the other of -18VDC. can it be connected in parallel to share a common ref voltage? if not, how do i make both sources to be of common ref voltage? tks
tell me about eletrical contractor
why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)