is the power of a single phase induction motor(Fans) is
constant under varying speeds?

Answer Posted / ahjaj

no,because its vary with the speed.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is there any relevant technique to produce power from light and heat energy of the sun simultaneosly from same rays of light?

1409


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

1554


1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.

1478


how to calculate percentage impedence at 75 deg C at normal tap

1797


sir, 3phase induction motor takes different pf and different KW in three phase while running,explain reason

1033






how can you size an automatic voltage regulator?

1865


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1572


substation+ plc system

1621


How may I get the maximum current capacity for a particullar size Alluminum or Copper cable if there is compulsion to use?

1448


How to calculate energy stored in a capacitance

685


8. A DYNAMOMETER TYPE WATTMETER RESPONDS TO THE.......

8483


What is error of a measurement?

621


Pl. share your experience about industrial-electronics repair of machine tool.

1447


What is contract demand in solar system?

1126


What are m circles?

657