Answer Posted / amit kumar singh
As far as the formula V=IR is concerned, yes it is
applicable to only DC circuit. But if we go by the concept
given by Sir George Simon Ohm, every circuit ehich contains
LINEAR LOAD, follows Ohm's Law, i.e. the current flowing
through any circuit is directly proportional to the voltage
applied across its ends provided the impedence of circuit
and frequency of source voltage remains constant.
| Is This Answer Correct ? | 32 Yes | 6 No |
Post New Answer View All Answers
How we calculat the NGR of 3phase Generator, Our generation voltage 11KV
Why the frequency of ac in india is 50 hz but in some other countries it is 60 hz.
How to measure current and voltage in an ELV circuit
What is the purpose of stand by earth fault protection for transformer ?
In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.
how much maximum load a 2 core (Single phase) 16mm aluminium wire can take ?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance
What is time response of the control system?
Explain in details how you would react to an unexpected incident when your supervisor or manager is not around to give instructions?
In a voltage-controlled current source A A current booster is never used B The load is always floated C A stiff current source drives the load D The load current equals Isc
What Maximam Gap Taibaar & Bush
how can we calculate the ratio of caustic soda and water in lrs.
If Polarization index of motor 8.75 at 500volts of medium voltage 4.16 KV motor what this mean winding good or bad pl answer if any reffrence book give me the link
How to megger test 11 kV cable and the acceptance IR value