Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

ohm's law is applicable to DC/AC/Both??

Answer Posted / amit kumar singh

As far as the formula V=IR is concerned, yes it is
applicable to only DC circuit. But if we go by the concept
given by Sir George Simon Ohm, every circuit ehich contains
LINEAR LOAD, follows Ohm's Law, i.e. the current flowing
through any circuit is directly proportional to the voltage
applied across its ends provided the impedence of circuit
and frequency of source voltage remains constant.

Is This Answer Correct ?    32 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How we calculat the NGR of 3phase Generator, Our generation voltage 11KV

3311


Why the frequency of ac in india is 50 hz but in some other countries it is 60 hz.

2137


How to measure current and voltage in an ELV circuit

4162


What is the purpose of stand by earth fault protection for transformer ?

2090


In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.

1871


how much maximum load a 2 core (Single phase) 16mm aluminium wire can take ?

2642


We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

1987


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1948


What is time response of the control system?

1097


Explain in details how you would react to an unexpected incident when your supervisor or manager is not around to give instructions?

8088


In a voltage-controlled current source A A current booster is never used B The load is always floated C A stiff current source drives the load D The load current equals Isc

1893


What Maximam Gap Taibaar & Bush

2321


how can we calculate the ratio of caustic soda and water in lrs.

5845


If Polarization index of motor 8.75 at 500volts of medium voltage 4.16 KV motor what this mean winding good or bad pl answer if any reffrence book give me the link

2123


How to megger test 11 kV cable and the acceptance IR value

2984