Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Integral and Derivative control?

Answer Posted / mohammed emaaduddin

In Integral control, the value of o/p at any given time is the integral of the error over that period of time.
In derivative control, the o/p is proportional to the derivative of the error..

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Introduce yourself which is not present in your biodata?

2377


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1611


how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?

5625


What is zone,loop/fire alarm system?

2571


I installed the smartplant instrument v8, but can not be opened, that always said: "INTools 2007 hardlock no found". So Could you help me how to do for that?

2008


Linear amplifier.

1958


steps for installing orifice plate?

1791


In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.

1897


Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .

1650


while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?

2146


what effects a surging can produce in the compressor

1854


How INtools is useful for routine Instrument maintenance?

2014


What is the start up procedure of desalter

3613


What is the diffrence between ff tx and non ff tx

3123


is there any digitel grevity meter availaible in the market by which we can measure specific gravity of a battery?

2166