Answer Posted / surender k
Turbo is functioning in two ways:
1#. Sucking & Releaseing hot fumes & smoke in open
atmosphere, which are coming from engine's combustion
chamber.
2#. Sucking the air from filter and supply it to combustion
chamber for fuel & air mixing.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
HOW TO CHECK THE VECTOR GROUP OF A TRANSFORMER YD11?
please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com
hi guys please tell me the procedure for mesuring the coil resistance of 3ph induction motor?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
Can you explain about Restricited earth fault protection scheme
Which type of DG need Netral Earthing?
what are problems caused by the pdu in rack server
Difference between Lugs and Thimbles
What is the maximum number of swithes that can be connected in series up to down stream point in an LV Distribution system?
How to identify the start and end of 3phase 12 lead motor if U1, U2, etc numberings are lost or erased.
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
1.4 What is meant by CT knee point voltage and how would you determine it
Zone of protection and tripping scheme of arc protection relay.
why the making current is more than then the breaking current and if its true then its about a controling circuit or breaker power contact points
how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids