can we use the step down transformer to step up transformer

Answer Posted / j.karthik

ya,its possible.. for ex: using a 11kv/415volt step down
transformer, in this primary voltage is 11kV and the
secondary voltage is 415volt(step down transformer)... now
we giving the input voltage to the 415volt side of the
transformer now the primary voltage is 415volt and secondary
voltage is 11kV(step up transformer).....
The step up and step down transformer is deponds upon
the input voltage is feeding side of the transformer(Primary
or secondary side)

Is This Answer Correct ?    7 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to protect a Dosing pumps/any sensitive equipment (single phase) from surge protection inside a food factory.

1275


What type of a DC motor would you use for a lift?

666


why chock were used in old tubelights but are not newest tubelights?

1449


what is your majour contributions in your present job

1340


What is Harmonics how it is produced and what is the method to control the same

1765






Tell me about ur past electrical maintanence job

1427


how we calculate the short circuit capacity of the busbar in LV & HT?

640


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1441


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1735


could an induction motor be used for regenerative braking in electric-train control? in this type of application would some scheme have to be devised to obtain low synchronous speeds while braking? would induction-motor drive, therefore, be suitable for passenger service?

1586


Differentiate between induced emf and self inductance?

598


we have a rewind motor of 2Hp,2800Rpm, 220Volt AC. how can we choose the running capacitor for this motor, any formula for that?

1486


What is the role of Dedicated earthing in UPS System?

2632


how to select the mpcbs and contactor for 3 phase 30 hp star delta motors.for plc control.and tell me the calaculation for future use.

1462


please send me the previous year's question papers of jindal GET exams

5510