Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is DG synchronization panel
plz explain the working!!!!!!!

Answer Posted / sharad

Two or more Dg synchronization Main Think Require is Those
Dg Frequency, Terminal Voltage, And Phase Sequence, are
same. Then synchronization Will Be Done.When Those Parameter
Matche synchronization panel Keep synchronizing Dg With
Their Prosses.synchronization panel Conect Two or More Dg
Synchronize With same capacity or veriable capcity.Or load
application.

Is This Answer Correct ?    21 Yes 16 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the current setting for different relay protection for transformer .

2304


EXPLIAN THE IMPORTANCE OF POLY PHASE CIRCUIT.

2167


I use 20 nos led tube 4feet, in pathway 100mtr approximate, so what size cable i use for lighting

1471


what is plunger and what's the use of it in motor alignment?

2640


what is the differebt between ac and dc fuse?

2336


What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?

2276


What are the two types of compensation?

1136


along with technical test papers

1606


What do you mean by a current transformer?

1091


What is the meaning of dedicated earthing?

2162


What is “pu” in electrical engineering?

1136


how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.

2150


I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2271


WANTCONTACT NUMBER & EMAIL/ WEBSITE TO CONTACT THE SECRETARY,MADHYA PRADESH LICENSING BOARD(ELECTRICAL),K- BLOCK,3RD FLOOR,SATPOODA BHAWAN,BHOPAL

2080


Diagram on interconnectivity of 11kv transformer with RMU (i.e, one incoming and two outgoing or two incoming and one outgoing)

2722