what is creepage distance in sub-station?

Answer Posted / deadzg_devil

Creepage Distance. Creepage is the shortest path between two conductive parts (or between a conductive part and the bounding surface of the equipment) measured along the surface of the insulation. A proper and adequate creepage distance protects against tracking, a process that produces a partially conducting path of localized deterioration on the surface of an insulating material as a result of the electric discharges on or close to an insulation surface. The degree of tracking required depends on two major factors: the comparative tracking index (CTI) of the material and the degree of pollution in the environment. Used for electrical insulating materials, the CTI provides a numerical value of the voltage that will cause failure by tracking during standard testing. IEC 112 provides a fuller explanation of tracking and CTI.1 Tracking that damages the insulating material normally occurs because of one or more of the following reasons:

*
Humidity in the atmosphere.
*
Presence of contamination.
*
Corrosive chemicals.
*
Altitude at which equipment is to be operated.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A d.c. Shunt motor is found suitable to drive fans because they require?

725


What is the formula to calculate the rating of power cable for three phase current.

1661


What are the advantages of a three-phase system over a single-phase system?

628


why -48 volts dc used in telecommucation

1976


What is the temperature PROFILE OF A FLUID W. R. T. Distance from a sphere to which it is IN CONTACT which is at constant temp.?

1629






Is it good to short Neutral and Ground in the PLC or DCS main Power supply. Pls give YES or NO with reasons...? Simarpreet

2045


does the Trivector Meter of three phase automatically takes care of the low power factor and gives the reading accordigly or it does not take care of the Power factor while giving the readings please explain

1400


what is the significance of cabability curve of alternator

1796


Explain the advantages and disadvantages of hydropower plant?

660


Explain the method to keep noises low in a control system?

652


Define resonant peak?

653


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2227


Discribe type of fault in DOL and stardelta startor.

1803


How efficiency of thermal plant can be improved?

750


What are the difference between normal application Transformer and Solar application Transformer?

1229