why 4 to 20 ma ,why not 0 to 20 or 3 to 15 or anything
Answer Posted / smruti senapati
with 0-20 ma you canot distinguish between minimum field
value and connection break.with 2-20 ma ,internal circuits
can distunguish between connection break of minimum
value.normally when the value is minimum the transmitter
will give you 4 ma while in case of connection breakage it
will give 0 ma...
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.
How to Calibrate Ultrasonic flow Transmitter in Field
what is basic difference between motion balance and force balance in pneumatic instrument?
any one can send me instrumentation previous interview papers? I prepare for MNC Company Interviews? my mail id- Rakesh.Golla@dodsaldxb.ae , and another mail rakesh.gvk@gmail.com
Why ac supply load cell is used? Can we use the dc supply load cell?
what is the difference between active & reactive power?
State bernoulli’s application.
what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????
Give 2 application of quartz crystal used for process parameter measurement.
Explain the working of an electronic level troll.
Name different types of bourdon tubes.
Specify ideal accuracy of flow element like orifice plate, Ventury, Annubar. Ultrasonic flow meter etc.
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
I faced several time siemens ps2 positioner automatically getting Chang in it's set point direction after auto calibration So is there any causes biside this or any permissives ?
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).