Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we use CVT (capacitive voltage transformer)in switch yard?

Answer Posted / ha

CVT means capacitor voltage transformer and it use in
substation that it is above 230KV.PT or VT measure voltage
and this parameter used for protection system.in the high
voltage used CVT insted VT and capacitors play divider
role. we can used from these capasitors for PLC system
until cost have been minimum.

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHY IL=IPH IN STAR AND WHY IPH=IL/1.732 IN DELTA? WHAT IS REASON BEHIND IT?

6249


In a flange coupling, the flange bolts are designed for

1070


What is boucholz relay and the significance of it in to the trformer?

1089


Why to keep capacitor bank off while generator running.

1735


Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks

1709


How many devices can be connected in one zone of FACP

2270


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1739


which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor

1908


What is hipot test procedure?

1410


Can we check ELCB constantly from R1 to R8 phase in 1 no DB?

1641


What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker

1943


What is the capacitance values of 132,220,400 & 765 kV current transformer

1862




2072


What happens if we run alternator on under frequency? 

2049


State superposition theorem?

1084