if transformer winding burn on dc supply then
why not alternator rotor winding please post
answer on y.sakhare@rediffmail.com
Answer Posted / k.prakashchandra
The windings in both the cases will not burn out if the
cooling is perfect.When it comes to motors or gen, it is
advisable to specify whether field or armature instead of
just rotor or stator.In case of large HT gen, the field is
the rotor.When Dc is applied and current is =V/DC
resistance.The same with the Tr.At the rated DC current, the
heating in tr will be less as there are no iron losses.
| Is This Answer Correct ? | 0 Yes | 10 No |
Post New Answer View All Answers
In TNC switch, is there any 1NO+1NC block ? and if we move over closing position, is ther any affect on trip position or vice versa?
r we are using in gas turbine mark (5) frame (6) (made in india Bhel 1997) Ā
What is the Load Capacity of Panther conductor (0.2) and dog conductor (0.2)
WHAT IS THE FAULT WHEN 100HP TURBINE MOTOR TRIPS, LIST THE FAULTS AND ITS TRABULESHOOTING TIPS.. MY AUTO TARNSFORMER STARTER TRIPS
I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.
What do you mean by reach and reach the point of the relay?
In which of the following case, the rotating magnetic field is reversed? A regenerative breaking B plugging C dynamic breaking D forward motoring
What is a commutator?
what is your aim
what is efficient motors and how it is different from normal induction motors
The 3 phase 400 hp 440 volt slip ring induction motor do not take one phase amps why ? The motor is running good condition
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
i completed my DEEE. and i want to electrical c license. how to get it..?
What is the formula to calculate the rating of a three phase miniature circuit breaker
what is relation between ct and pt ratio with multiplication factor of a energy meter? is there any other factor on which multification factor depend?