Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we should use delta connection in primary and star
connection in an distribution transformer, which converts
400v a.c. voltage to 33kv.

Answer Posted / premsingh

we use delta connection in prymary becouse in prymary we
need step up the voltege & in delta connection line voltage
is more then phase voltage & we use star in secondry bcoz
in star connection provide us nutral which is nessery for
distibution because all home applances work with phase &
nutral so we use star connection in distribution end.

Is This Answer Correct ?    0 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.

2444


testing of Vector Group – YNaoD II

2927


Please tell me the formulaes while designing a substation for power Calculations in designing a 33 KV Substation?????

1814


we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.

2061


how is control wiring coding is done in a CRP panel ?

2020


What type of fittings and electrical accessories can be install in radiation area ?

1748


What is reverse power relay?

1182


how cables go in and come out for distribution from the feeder pillar box?

2085


PAC and simple Ac different

1520


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2816


What will happen if the armature resistance is in minimum position and the field resistance is in maximum position while starting the motor

1609


what is rating boiler

1988


what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated

1979


what is meant by 2 within a star in a voltmeter dial?

2073


What is a diode?

1061