if transformer winding burn on dc supply then
why not alternator rotor winding please post
answer on y.sakhare@rediffmail.com
Answer Posted / yogesh
every conductor produces magnetic field around it when you give ac or dc supply.but in ac supply the flux is alternating which produces self induced emf in winding which opposes supply vtg so currunt limits.but in dc supply there is no self induced emf.so when dc supply given to xmer no self induced emf produced to limit the current and in alternator or dc motor there also no induced emf produced but to limit the current the winding resistance made high ie above 100 ohms wheres xmer wdg resistance is in points range ie 0.1 ohm etc
| Is This Answer Correct ? | 8 Yes | 1 No |
Post New Answer View All Answers
what reactive how to maintain
why we use two slope(differential & restraining) in differential relay.but in busbar protection differential we are using only one slope?please explain
how does an centrifugal and screw type chiller will work. which chiller efficiency is high and why.
Why current shoots up in the secondary on the knee point voltage during saturation test of CT? How core saturation effects the secondary current (while the primary side is open)? What the logic behind this?
What is the problem of internal failure in ship engine telegraph system norcontrol?
i want to learn control schedule for 11kv panel? can any one send the detailed control schedule?
What was the Dg set radiator and lube oil temperatures trip in ACB
hi pal, i am vengatesh from tamilnadu(chidambaram),i have called for the written test for the post of jr executive(ELECTRICAL) of AAI ,I dont know about the question paper pattern,so any kindly help me to face the examination,post me the model question papers and some tips to write my examination to (vengi.annadurai@gmail.com)
why dc is used in control circuits for MV & LV switchgeras instead of ac
what is the relation between knowing of the distance between power transformer and the capacitor feeder in case of parallel operation
How can we decide cable size from HT panel to Transformer? Please give you reply with some examples.
in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses? the second question is-generation is depends on LV winding? or LV winding design for generation voltage?
can u give me a brief idea about power line carrier communication ??
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
What is mean by STUB protection?